1/2TBE&J Turnbuckle for ROHN Tower 1/2 x 12 inch Eye to Jaw

Follow Us on Twitter Printer Friendly Tell a Friend
1/2 x 12 inch Eye to Jaw Turnbuckle 1/2TBE&J
Price: $17.95
Mfr. Code: 1/2TBE&J-12

Qty:

Highlights:
Tension Down Guys
Heavy Duty
11,000 lbs. ultimate Strength

Description
ROHN 1/2TBE&J 1/2" x 12" Eye to Jaw Turnbuckle
Federal Spec FF-T-791B Type 1 Form 1; Forged, Hot Dip Glavanized, Open Body, Working Load Limit: 2200 lbs., Ultimate Strength: 11000 lbs.

spec. sheet


Spec. Sheet


Get Adobe Reader




Typical Use: when attaching and tensioning ROHN Tower Down Guy terminations (3/16" Strand via Pre-formed deadend and 5/16THH, 1/4" Bare Strand via Cable Clamps and 5/16THH, 1/4" Strand via Pre-formed deadend and 3/8THH, or 5/16" Bare Strand via Cable Clamps and 3/8THH) to Closed Eye GAR30 or Integral Equalizer Plate Anchors (like GAC3455TOP or GAC5655TOP). 11,000 lbs. Ultimate Strength. Eye to Jaw Turnbuckles typically attach the Tower Down Guy Strand (via a Big Grip Pre-Formed Dead-End and a Heavy Open Thimble) on one end to the Down Guy Equalizing Plate or Closed Single Eye Anchor (the ones that Holes as the attachment Method, ie; R-GAR30 and R-GAC3455) on the other end. Consult ROHN Catalog Links at Footer Section below for ROHN 25G 45G 55G 65G Tower Guy wire Details for Various Wind Loads.
Compare to ROHN R-1/2TBE&J 1/2 inch Eye to Jaw Turnbuckle!

Availability: Usually ships in 24 Hrs
Shipping: Can ship anywhere
Tower Down Guy & Anchor
ROHN Tower Down Guy and Anchor Materials Tower Down Guy and Anchor Material included here are that which comprise the Kits specified by various dated and current ROHN catalogs. Reference the Pre-Engineered Kit Packages in the 25G 45G 55G 65G Buyer's Guides by Height and Wind load to build or supplement your ROHN G-Series Guyed Tower to current REV. G Specifications. New REV. G and Older REV. F Specification Sheets may be found in the various "ROHN Tower" links in the Footer section below and are made available only for study and reference. Any Departure or Questions of variance from the Pre-Engineered formats should be forwarded to and engaged by a Engineer qualified to make such determinations.

ROHN Complete Tower ID Nomenclature

GUIDELINES FOR THE PREPARATION OF A GEOTECHNICAL REPORT

I. PURPOSE AND INTENT

a) The intended purpose of these guidelines is to assist the customer and/or owner to retain the services of a Geotechnical Engineer.

b) It is not ROHN’s purpose or intent to supercede the Geotechnical Engineer’s knowledge, judgement and/or experience. It is the Geotechnical Engineer’s responsibility to add or delete from these items, based on local site conditions and other factors.

c) Additional information is provided in ANSI/TIA-222-G Annex G “Geotechnical Investigations”.

II. DISCLAIMER

a) ROHN will not accept any liability, either expressed or implied, for the use of, and omissions in, these guidelines.

III. EXPLORATORY BORINGS

a) Borings should be taken at tower legs for self-supporting towers and at the base and anchor points for guyed towers. For small self-supporting towers, two borings may suffice. For large self-supporting towers, one boring should be taken at each tower leg. A “small” self-supporting tower is assumed to have a face width less than 20 feet and a compression load less than 50 kips per leg. For pole structures, one boring may suffice.

b) The minimum boring depth should be 30 feet for pole structures, self-supporting towers and guyed tower bases. For guyed tower anchors, the minimum depth should be 15 feet. The actual depth of boring must be determined by the Geotechnical Engineer based on reactions, soil conditions and the type of foundation recommended.

c) If borings cannot be advanced to the desired depth, rock corings should be taken. Rock Quality Designation (RQD) values and compressive strengths should be determined.

IV. GEOTECHNICAL REPORT

a) The following properties, for each soil layer encountered, should be determined by field or laboratory testing and summarized in the geotechnical report:

1. Soil classification and elevations
2. Standard penetration values
3. Unconfined compression strength
4. Angle of internal friction
5. Cohesion
6. “In-Situ” soil density and moisture content
7. Rock quality designation (RQD) and percent rock sample recovered
8. Other properties unique to site conditions

b) The following items should be discussed in the geotechnical report:

1. Geological description of site
2. Observed and expected ground water conditions
3. Expected frost penetration depth
4. Corrosion potential of soil and corrosion protection recommendations
5. Site access and potential construction difficulties
6. Dewatering or site drainage requirements
7. Backfill material recommendations
8. Settlement considerations
9. Additional information to aid foundation designer
10. Recommended types of foundations
11. Design parameters for uplift, download and lateral load
12. Factor of safety considered when allowable vs. ultimate design parameters are provided
13. Recommended construction techniques and inspections
Your Cart
Credit Cards Taken
Your shopping cart is empty!
We Ship Fast!
Your Orders leave Daily! UPS... What can Brown do for You?!United States Postal ServiceR+L Carriers... Value Added Advantages!
Click here for BBB Business Review

This Site is Operated and Maintained By Three Star Incorporated
© 2008-2011 cableandwireshop.com All Rights are Reserved and Enforced
Three Star Inc. 120 Simpson Rd. Kissimmee, FL 34744 USA
* 877-660-0974 (407) 944-8856 FAX (407) 944-8872 *
E-mail Webmaster Via the "Contact Us" Page please
All Site Hosting Services Provided by Intelli-Net

God Bless America!
U.S. Military Welcome!