ROHN 65SS050 Complete 50 Foot Self Supporting Tower


This Product Order Supplies the Following BOM (Less Foundation and Installation) in accordance for Use as a Self Supporting 50 Foot ROHN 45G Tower with EPA's (Effective Projected Area) Ratings for 70, 80 or 90 MPH (No Ice). Refer to Larger Image, Brochure or Footer Links at the Bottom of the Page below for Ice Loading and EPA Information.
 

 

THIS KIT INCLUDES
QUANTITY PART NUMBER DESCRIPTION
1 65G 10' Tower Section
2 6520G 20' Tower Section
3 65JBK Bolt Kit for 65G Tower Section
1 CP4A Top Cap Plate Kit
1 SB65GH Base Section
2 BGK2G (OPTIONAL) Ground Kit
1 ACWS Anti-Climb Warning Sign
1 ASSEMBLY GUIDE

 


This 65G Tower is to be used in a Self-Supporting Configuration according to Use and Foundation Specifications in the ROHN Catalog. This Height Configuration relies on a R-SB65G Embedded in a Concrete Foundation Specified by Engineering. As a Free-Standing, Self-Supporting Structure, a 70 MPH rated 65G Tower can rise to a maximum of 80 feet. Consult ROHN 65G Catalog Links of the Footer Section at Bottom of Page for more ROHN 65G Tower Configuration, Foundation and Grounding Detail Information.

 

Warranty Sheet

 
Specification Sheet
Spec Sheet
ROHN 65G 50 Foot Self Supporting Tower R-65SS050 ROHN 25G 45G 55G 65G Universal Side Arm Mount - SA253UA - $225.00

ROHN SA253UA Universal Side Arm Antenna Mount for 25G 45G 55G 65G Tower
Double Side Arm Mounts for lightweight broadband, scada and two-way antennas. Fits 25G, 45G, 55G and 65G towers. Extends 3' off the tower with 2.25 inch O.D. Pipe...

Read More
ROHN 65G 50 Foot Self Supporting Tower R-65SS050 ROHN 3 Foot Side Arm Mount R-KH6100A - $675.00

ROHN KH6100A 3 Foot Side Arm Antenna Mount
Side Arm Mount for Antenna Mounting on 65G towers. Extends 3' off the tower, supplied with a 7 foot by 2.375 inch (2-3/8") O.D. Pipe....

Read More
ROHN 65G 50 Foot Self Supporting Tower R-65SS050 ROHN 6 Foot Side Arm Mount R-KY1048A - $895.00

ROHN KY1048A 6 Foot Side Arm Antenna Mount
Side Arm Mount for Antenna Mounting on 65G towers. Extends 6' off the tower, supplied with a 5 foot by 2.375 inch (2-3/8") O.D. Pipe....

Read More
ROHN 65G 50 Foot Self Supporting Tower R-65SS050 ROHN 65G Adjustable 18-30" House Bracket R-KH1014 - $745.00

ROHN KH1014 18 to 30 inch 65G Adjustable House Bracket
for Standoff from 18, up to 30", Specified for use in ROHN 65G Bracketed Tower Installations...

Read More
ROHN 65G 50 Foot Self Supporting Tower R-65SS050 ROHN 65G Tower Face 4.5 inch O.D. Dish Mount R-DM654 - $425.00
ROHN DM654 Tower Top 4.5 inch O.D. Dish Mount
Face Mount includes 2 Angled Steel Cross-Members that Bolt directly to any of the 3 Faces of a Standard 65G Tower Section. 5 Foot x 4 inch STD (4.5 inch O.D.) Pipe connects with U-bolts to 65G Tower Section Brackets...

Read More
ROHN 65G 50 Foot Self Supporting Tower R-65SS050 ROHN 65G Tower Face Dish Mount with Tie-Back R-DM654TB - $780.00
ROHN DM654TB Tower Top 4.5 inch O.D. Dish Mount
Face Mount includes 3 Angled Steel Cross-Members that Bolt directly to any of the 3 Faces of a Standard 65G Tower Section (1 used as Tie-Back). 5 Foot x 4 inch STD (4.5 inch O.D.) Pipe connects with U-bolts to 65G Tower Section Brackets...

Read More
ROHN 65G 50 Foot Self Supporting Tower R-65SS050 ROHN 65G Tower Side 2.375 inch O.D. Dish Mount R-KY509 - $425.00
ROHN KY509 2.375 inch O.D. Side Dish Mount
Side Mount includes 2 Angled Steel Cross-Members that Bolt directly to any of the 3 Faces of a 65G Tower Section. 5 Foot x 2 inch STD (2-3/8 inch O.D.) Pipe connects with U-bolts and Brackets to Tower Section...

Read More
ROHN 65G 50 Foot Self Supporting Tower R-65SS050 ROHN 65G Tower Side 4.5 inch O.D. Dish Mount R-KY510 - $734.00
ROHN KY510 4.5 inch O.D. Side Dish Mount
Side Mount includes 2 Angled Steel Cross-Members that Bolt directly to any of the 3 Faces of a 65G Tower Section. 5 Foot x 4 inch STD (4-1/2 inch O.D.) Pipe connects with U-bolts and Brackets to Tower Section...

Read More
ROHN 65G 50 Foot Self Supporting Tower R-65SS050 ROHN 65G Anti-Climb Tower Section Panels ACL65G - $895.00

ROHN VW915A 65G Anti-Climb Panels (3) for Base Tower Section


3 ACL Anti-Climb Panels for Installation onto an Existing 45G 55G Base Tower Section...
This Item Ships LTL Freight ONLY...
Click Here for: Shipping Calculator!

Read More
ROHN 65G 50 Foot Self Supporting Tower R-65SS050 ROHN 65G Section Cap Plate Kit R-CP4A - $84.95

ROHN CP4A 65G Section Cap Plate Kit
The ROHN R-CP4A cap plate kit is designed for use with a ROHN 65G tower section. The cap plate kit contains three (3) cap plates and all required nuts and bolts for installation to prevent debris, animal and insect deposits.

Read More
ROHN 65G 50 Foot Self Supporting Tower R-65SS050 ROHN 65G Tower Work Platform Attachment R-WPCC65G - $1,350.00

ROHN WPCC65G 65G Tower Work Platform Platform
Bolts into place at any level (U-Bolts included)...

Read More
ROHN 65G 50 Foot Self Supporting Tower R-65SS050 ROHN Leg Mounted Beacon Plate R-APL4HA - $165.00

ROHN 65G APL4HA Leg Mounted  Beacon Plate
Top Plate and Beacon Mount for 65G, 5N and 6N Tower Sections...

Read More
ROHN 65G 50 Foot Self Supporting Tower R-65SS050 ROHN Lightning Rod Plate Kit R-VW133 - $69.00

ROHN VW133 Lightning Rod Plate Kit
Includes Lightning Rod Plate, (2) Cap Plates, with bolts and nuts for installation onto a 65G leg joint flange, does not include R-LRCL Lightning Rod (available separately)...

Read More
ROHN 65G 50 Foot Self Supporting Tower R-65SS050 ROHN Lightning Rod R-LRCL - $145.00

ROHN LRCL 5 Foot 5/8" Copper Clad Lightning Rod
5 foot by 5/8 inch copper clad Lightning Rod for Tower installation, threaded with nuts. Installs on most Tower Series Top/Beacon Plates and attachments made for this purpose...

Read More
ROHN 65G 50 Foot Self Supporting Tower R-65SS050 ROHN BGK2G Tower Base Ground Kit - $79.00

ROHN BGK2G Tower Base Section Grounding Kit
Primarily for 25G,45G,55G and 65G REV. F Towers, also used in Self-Supporting Tower Kits. Comprises enough material to ground 1 Tower Base Section Tubular Rail. Consists of (1) 5/8"x8' Ground Rod, (1) Rod Clamp (1) J-Clamp 1-1/4 to 2 inch and 10 feet of #4 Solid Copper Wire...

Read More
ROHN 65G 50 Foot Self Supporting Tower R-65SS050 ROHN Tower ACWS Anti-Climb Warning Sign - ACWS - $38.00

ROHN ACWS Anti Climb Warning Sign
The same Anti Climb Warning Assembly Kit from the ROHN Factory for placement on new tower installations and replacement on existing tower sites where the sign and sticker have faded due to exposure. One of the items on your yearly checklist...

Read More
ROHN 65G 50 Foot Self Supporting Tower R-65SS050 ROHN 65g Top Plate Mount KC970  - $319.95

ROHN KC970 Top Plate Mount
For Installing Beacon Lights , Cameras...

Read More
ROHN 65G 50 Foot Self Supporting Tower R-65SS050 ROHN Universal Leg Mid Level Beacon Mount R-APL1258UM - $695.00

ROHN APL1258UM Mid Level Universal Leg Beacon Mount
For Installing Beacon Lights on any size or angle leg on any Tower Section level...

Read More
Product isn't rated yet. Write a review.

The Self-Supporting G-Series Towers offer an easy, low-cost solution to get light weight antennas in the air quickly. By using the G-Series tower as a self-supporting structure, you minimize land area usage. They are functional in a wide variety of wind speeds, with and without ice. See ROHN´s standard design to help identify the right structure for your project. Theses are the same sturdy, robust tower sections that ROHN has fabricated for years. Each larger model allows for more loading capacity.

Wind Loading, Antenna Loading and Wind Survivability ratings vs. Height Documentation Provided by ROHN is available here as a Resource, but is by no means complete by itself or a susbstitution for Engineering Conducted Specific to your Application. Contact Us with any Questions you may have regarding Use prior to Purchase. All Information regarding the ROHN 55G Tower line, Parts and Accessories is as accurate and complete as we can possibly provide given that this Resource Offering is subject to change without Notice and is beyond Our Control.


ROHN Self Supporting Tower Rev.F

ROHN Self Supporting Tower Rev.G

DESIGN NOTES:
1.
Tower designs are in accordance with approved national standard ANSI/EIA-222-F.
2. All towers must have "fixed" bases. Pinned bases may not be used.
3. Designs assume transmission lines symmetrically placed as follows:
25G Tower - One 5/8" Line on each face ( Total =3)
45G Tower - One 7/8" Line on each face ( Total = 3 @ 7/8" & 3 @ 1/2")
65G & 65G Towers - Two 7/8" Lines on each face ( Total =6)
4. Antennas and mounts assumed symmetrically placed at tower apex.
5. Allowable antenna areas assume all round antenna members.
6. Allowable flat-plate antenna areas, based on EIA RS-222-C, may be obtained by multiplying areas shown by 0.6.
7. Standard foundation designs are based on Rev. F normal soil and Rev. G presumptive clay soil parameters. .

FEATURES:
o
Completely hot-dip galvanized after fabrication to provide absolute corrosion protection.
o Cross bracing is formed by a continuous solid rod bracing in a zig-zag pattern for strength.
o Pre-engineered loading charts meet varying individual specs and site conditions.
o Typical uses include small dishes, broadband, security and two-way communication.


ROHN 25G Buyers Guide



ROHN G-Series Self Supporting Towers


Get Adobe Reader



This ROHN G-Series Self Supporting Towers Guide will answer many questions you may have on this Product Line.


GUIDELINES FOR THE PREPARATION OF A GEOTECHNICAL REPORT

I. PURPOSE AND INTENT

a) The intended purpose of these guidelines is to assist the customer and/or owner to retain the services of a Geotechnical Engineer.

b) It is not ROHN´s purpose or intent to supercede the Geotechnical Engineer´s knowledge, judgement and/or experience. It is the Geotechnical Engineer´s responsibility to add or delete from these items, based on local site conditions and other factors.

c) Additional information is provided in ANSI/TIA-222-G Annex G "Geotechnical Investigations".

II. DISCLAIMER

a) ROHN will not accept any liability, either expressed or implied, for the use of, and omissions in, these guidelines.

III. EXPLORATORY BORINGS

a) Borings should be taken at tower legs for self-supporting towers and at the base and anchor points for guyed towers. For small self-supporting towers, two borings may suffice. For large self-supporting towers, one boring should be taken at each tower leg. A "small" self-supporting tower is assumed to have a face width less than 20 feet and a compression load less than 50 kips per leg. For pole structures, one boring may suffice.

b) The minimum boring depth should be 30 feet for pole structures, self-supporting towers and guyed tower bases. For guyed tower anchors, the minimum depth should be 15 feet. The actual depth of boring must be determined by the Geotechnical Engineer based on reactions, soil conditions and the type of foundation recommended.

c) If borings cannot be advanced to the desired depth, rock corings should be taken. Rock Quality Designation (RQD) values and compressive strengths should be determined.

IV. GEOTECHNICAL REPORT

a) The following properties, for each soil layer encountered, should be determined by field or laboratory testing and summarized in the geotechnical report:

1. Soil classification and elevations
2. Standard penetration values
3. Unconfined compression strength
4. Angle of internal friction
5. Cohesion
6. "In-Situ" soil density and moisture content
7. Rock quality designation (RQD) and percent rock sample recovered
8. Other properties unique to site conditions

b) The following items should be discussed in the geotechnical report:

1. Geological description of site
2. Observed and expected ground water conditions
3. Expected frost penetration depth
4. Corrosion potential of soil and corrosion protection recommendations
5. Site access and potential construction difficulties
6. Dewatering or site drainage requirements
7. Backfill material recommendations
8. Settlement considerations
9. Additional information to aid foundation designer
10. Recommended types of foundations
11. Design parameters for uplift, download and lateral load
12. Factor of safety considered when allowable vs. ultimate design parameters are provided
13. Recommended construction techniques and inspections

Products   Recently Viewed