ROHN 65G 10 Foot Camera Tower R-65SS010CT

Highlights

Hot Dip Galvanized
Bolted Flange Joints
Zig-Zag Rod Bracing
1.9" Steel Tubing
Side Rails
24-1/4" Equalateral
Triangular Design
Can be used in:
Self Support Config

Bulk Quantities Available Here!

Price: $2,794.00
Manufacturer Code: 65SS010CT
Grounding:
Qty:
Availability: Usually ships in 1 week
Shipping: Can ship only within USA

ROHN 65SS010CT Complete 10 Foot Camera Tower

 

Rohn 65SS020CT - 10' Freestanding G-Series Camera towers offers an easy low cost solution  . Hot Dipped Galvanized for corrosion protection . All sections are tubulor and feature 1.9" OD pipe legs and cross bracing is formed by a continuous 3/8" solid rod bracing into a zig-zag pattern for strength . BGK2G Grounding is optional . Includes short base section, tower sections,  and 3/16” top mounting plate with attachment hardware .All towers have "FIXED " bases . 

 

This Product Order Supplies the Following BOM (Less Foundation and Installation) in accordance for Use as a Self Supporting 10 Foot ROHN 65G Camera Tower with EPA's (Effective Projected Area) Ratings for 70, 80 or 90 MPH (No Ice). Refer to Specification for Larger Image, Brochure ,Install guide and all 65G Kits Ice Loading and EPA Information.

 

 

THIS KIT INCLUDES
QUANTITY PART NUMBER DESCRIPTION
1 65G 10' Tower Section
1 65JBK Bolt Kit for 65G Tower Section
1 KC970  3/16" Top Mounting Plate 
1 SB65GH Base Section
2 BGK2G (OPTIONAL) Ground Kit
1 ACWS Anti-Climb Warning Sign
1 ASSEMBLY GUIDE

 

This 65G Camera Tower is to be used in a Self-Supporting Configuration according to Use and Foundation Specifications in the ROHN Catalog. This Height Configuration relies on a R-SB65GH Embedded in a Concrete Foundation Specified by Engineering. As a Free-Standing, Self-Supporting Structure, a 70 MPH rated 65G Tower can rise to a maximum of 50 feet. Please Consult 3 Star Inc  for more ROHN 65G Tower Configuration, Foundation and Grounding Detail Information.

 

Site-specific designs are available upon request

 

 

 

Specification Sheet
Spec Sheet
ROHN 65G 10 Foot Camera Tower R-65SS010CT ROHN R-BGK2GGX Tower Base Ground Kit - $97.95
ROHN BGK2GGX Tower Base Section Grounding Kit
New REV. G Grounding Kit for 55G and 65G Guyed Towers. Comprises enough material to ground 1 Tower Base Section Tubular Rail. Consists of (1) 5/8"x10' Ground Rod, (1) Rod Clamp (1) CPC1.5/2 Rail Clamp and 15 feet of 7/16 6x25 EIP IWRC RRL Wire Rope...

Read More
ROHN 65G 10 Foot Camera Tower R-65SS010CT ROHN Lightning Rod R-LRCL - $145.00

ROHN LRCL 5 Foot 5/8" Copper Clad Lightning Rod
5 foot by 5/8 inch copper clad Lightning Rod for Tower installation, threaded with nuts. Installs on most Tower Series Top/Beacon Plates and attachments made for this purpose...

Read More
ROHN 65G 10 Foot Camera Tower R-65SS010CT ROHN Lightning Rod Plate Kit R-VW133 - $69.00

ROHN VW133 Lightning Rod Plate Kit
Includes Lightning Rod Plate, (2) Cap Plates, with bolts and nuts for installation onto a 65G leg joint flange, does not include R-LRCL Lightning Rod (available separately)...

Read More
ROHN 65G 10 Foot Camera Tower R-65SS010CT ROHN 25G 45G 55G 65G Universal Side Arm Mount - SA253UA - $225.00

ROHN SA253UA Universal Side Arm Antenna Mount for 25G 45G 55G 65G Tower
Double Side Arm Mounts for lightweight broadband, scada and two-way antennas. Fits 25G, 45G, 55G and 65G towers. Extends 3' off the tower with 2.25 inch O.D. Pipe...

Read More
ROHN 65G 10 Foot Camera Tower R-65SS010CT ROHN 3 Foot Side Arm Mount R-KH6100A - $675.00

ROHN KH6100A 3 Foot Side Arm Antenna Mount
Side Arm Mount for Antenna Mounting on 65G towers. Extends 3' off the tower, supplied with a 7 foot by 2.375 inch (2-3/8") O.D. Pipe....

Read More
ROHN 65G 10 Foot Camera Tower R-65SS010CT ROHN 6 Foot Side Arm Mount R-KY1048A - $895.00

ROHN KY1048A 6 Foot Side Arm Antenna Mount
Side Arm Mount for Antenna Mounting on 65G towers. Extends 6' off the tower, supplied with a 5 foot by 2.375 inch (2-3/8") O.D. Pipe....

Read More
ROHN 65G 10 Foot Camera Tower R-65SS010CT ROHN 65G Tower Face 4.5 inch O.D. Dish Mount R-DM654 - $425.00
ROHN DM654 Tower Top 4.5 inch O.D. Dish Mount
Face Mount includes 2 Angled Steel Cross-Members that Bolt directly to any of the 3 Faces of a Standard 65G Tower Section. 5 Foot x 4 inch STD (4.5 inch O.D.) Pipe connects with U-bolts to 65G Tower Section Brackets...

Read More
ROHN 65G 10 Foot Camera Tower R-65SS010CT ROHN Universal Straight / Tapered 3' Side Arm Mount SA324A - $595.00

ROHN SA324A Universal 3Straight/Tapered' Side Arm Antenna Mount 
Double Side Arm Mounts for WISP , broadband, scada and two-way antennas. Fits RT Light , Medium & Heavy  towers. Extends 3' off the tower - For tower legs  2.38 to 4.50" inch O.D. ...

 

Read More
ROHN 65G 10 Foot Camera Tower R-65SS010CT ROHN 65G Adjustable 18-30" House Bracket R-KH1014 - $745.00

ROHN KH1014 18 to 30 inch 65G Adjustable House Bracket
for Standoff from 18, up to 30", Specified for use in ROHN 65G Bracketed Tower Installations...

Read More
ROHN 65G 10 Foot Camera Tower R-65SS010CT ROHN 65G Tower Work Platform Attachment R-WPCC65G - $1,350.00

ROHN WPCC65G 65G Tower Work Platform Platform
Bolts into place at any level (U-Bolts included)...

Read More
ROHN 65G 10 Foot Camera Tower R-65SS010CT ROHN 65G Anti-Climb Tower Section Panels ACL65G - $895.00

ROHN VW915A 65G Anti-Climb Panels (3) for Base Tower Section


3 ACL Anti-Climb Panels for Installation onto an Existing 45G 55G Base Tower Section...
This Item Ships LTL Freight ONLY...
Click Here for: Shipping Calculator!

Read More
Product isn't rated yet. Write a review.

ROHN Camera Towers

ROHN structures can be designed to be utilized for security towers and surveillance applications. Our security towers are supporting cameras at military and government installations around the world. We have both solid and tubular security tower designs and all welded or knock-down designs to meet your security needs.

The all welded 65G tower sections can support 14.5 square feet of camera in 90mph, ½" ice conditions. ROHN has standard 65G security camera towers from 10´ up to 50´. ROHN also designs site-specific towers for security applications in all wind and ice conditions. Our rigid designs limit tower top movement to help ensure camera functionality even through severe weather conditions.


STANDARD VG SELF-SUPPORTING CAMERA TOWERS (all-welded)

REV. G:

110 MPH 3-SEC GUST WIND SPEED (NO ICE),

40 MPH 3-SEC GUST WIND SPEED (3/4" ICE),

CLASS II , EXPOSURE C , TOPO CATEGORY 1

SEISMIC COEFFICIENT  S <1.0

 

ROHN 65G Camera Tower

STANDARD VG SELF-SUPPORTING CAMERA TOWERS (field bolted)

REV. G:

110 MPH 3-SEC GUST WIND SPEED (NO ICE),

40 MPH 3-SEC GUST WIND SPEED (3/4" ICE),

CLASS II , EXPOSURE C , TOPO CATEGORY 1

SEISMIC COEFFICIENT  S <1.0

 

ROHN Self Supporting Tower Rev.G

DESIGN NOTES:

1. Tower designs are in accordance with ANSI/TIA/222-G.

2. Camera and mount assumed symmetrically placed at tower top.

3. Tower design assumes one 7/8" line on each tower face.

4. Assembly drawings and standard foundation details are provided with the tower.

5. Standard foundation illustrated is for general information only and is based on Rev G presumptive clay soil parameters.

 

FEATURES:
o
Completely hot-dip galvanized after fabrication to provide absolute corrosion protection.
o Pre-engineered loading charts meet varying individual specs and site conditions.
o Typical uses include small dishes, broadband, security and two-way communication.


ROHN G-Series Self Supporting Towers



ROHN G-Series Self Supporting Towers


Get Adobe Reader



This ROHN G-Series Self Supporting Towers Guide will answer many questions you may have on this Product Line.


GUIDELINES FOR THE PREPARATION OF A GEOTECHNICAL REPORT

I. PURPOSE AND INTENT

a) The intended purpose of these guidelines is to assist the customer and/or owner to retain the services of a Geotechnical Engineer.

b) It is not ROHN´s purpose or intent to supercede the Geotechnical Engineer´s knowledge, judgement and/or experience. It is the Geotechnical Engineer´s responsibility to add or delete from these items, based on local site conditions and other factors.

c) Additional information is provided in ANSI/TIA-222-G Annex G "Geotechnical Investigations".

II. DISCLAIMER

a) ROHN will not accept any liability, either expressed or implied, for the use of, and omissions in, these guidelines.

III. EXPLORATORY BORINGS

a) Borings should be taken at tower legs for self-supporting towers and at the base and anchor points for guyed towers. For small self-supporting towers, two borings may suffice. For large self-supporting towers, one boring should be taken at each tower leg. A "small" self-supporting tower is assumed to have a face width less than 20 feet and a compression load less than 50 kips per leg. For pole structures, one boring may suffice.

b) The minimum boring depth should be 30 feet for pole structures, self-supporting towers and guyed tower bases. For guyed tower anchors, the minimum depth should be 15 feet. The actual depth of boring must be determined by the Geotechnical Engineer based on reactions, soil conditions and the type of foundation recommended.

c) If borings cannot be advanced to the desired depth, rock corings should be taken. Rock Quality Designation (RQD) values and compressive strengths should be determined.

IV. GEOTECHNICAL REPORT

a) The following properties, for each soil layer encountered, should be determined by field or laboratory testing and summarized in the geotechnical report:

1. Soil classification and elevations
2. Standard penetration values
3. Unconfined compression strength
4. Angle of internal friction
5. Cohesion
6. "In-Situ" soil density and moisture content
7. Rock quality designation (RQD) and percent rock sample recovered
8. Other properties unique to site conditions

b) The following items should be discussed in the geotechnical report:

1. Geological description of site
2. Observed and expected ground water conditions
3. Expected frost penetration depth
4. Corrosion potential of soil and corrosion protection recommendations
5. Site access and potential construction difficulties
6. Dewatering or site drainage requirements
7. Backfill material recommendations
8. Settlement considerations
9. Additional information to aid foundation designer
10. Recommended types of foundations
11. Design parameters for uplift, download and lateral load
12. Factor of safety considered when allowable vs. ultimate design parameters are provided
13. Recommended construction techniques and inspections

Products   Recently Viewed
My Cart
Credit Cards Taken
Your shopping cart is empty!
We Ship Fast!
Your Orders leave Daily! UPS... What can Brown do for You?!United States Postal ServiceR+L Carriers... Value Added Advantages!