Cat5e Riser Rated Network Cable SBC Blue CMR 500 Feet

Highlights
  • 10 Base-T (IEEEE802.3)

    100Vg-AnyLan (IEEEE802.12)

    Token Ring (IEEEE802.5)

    100 Base-T (IEEEE802.3)

    FDDI/CDDI 100 Mbps

    ATM 155, 622 Mbps

    1000 Base-T

Price: $52.45
Manufacturer Code: CAT5e-BL-5
Qty:
Availability: Usually ships in 24 Hrs
Shipping: Can ship anywhere
SCP Cat5e-BL 500' Cat5e Riser Rated Cable 4 Pair 24AWG SBC UTP CMR PVC Jacket Blue
Enhanced Category 5 at 350 MHz Ethernet Cable in a Pull-Box for Businesses and Home Networks alike. This 24AWG / 4 Pair Cable Features Solid Bare Copper UTP CMR Rating (Non-Plenum Riser) in a Blue PVC Jacket with rip cord and external footage marking.

Cable Specifications:
Conductor: 24AWG Bare Solid Copper
Insulation: Solid Polyethylene

Industry Standards:
(UL) or (ETL) listed
ANSI/TIA/EIA 568B.2
ISO/IEC/11801

Applications:
10 Base-T (IEEEE802.3)
100Vg-AnyLan (IEEEE802.12)
Token Ring (IEEEE802.5)
100 Base-T (IEEEE802.3)
FDDI/CDDI 100 Mbps
ATM 155, 622 Mbps
1000 Base-T
Cat5e made by BPI 55-C5X-4P24 Sewell Direct Superior Essex Coleman Cable 992750502 992750505 992700606 Anixter BELDEN 1583A 1592A Structured Cable Products Cat5e-BL or Vertical Cable 054-445BL


Note: Cat5e cable is still limited to a maximum of 328 ft (100 m) in length that should include the length of patch cables that interconnect equipment. Cat 5e cable performance characteristics and test methods are defined in TIA/EIA-568-B.2-2001. Cat5e solid conductors are for distribution (typically) whereas Stranded conductors are usually reserved for flexible needs such as patch cords and cables. AWG conductor sizing is typically 24, comes in pairs of 4, and UTP (Unshielded Twisted Pair). When using LAN (Local Area Network) cable such as this is used in areas of likely ambient interference that would slow performance from the 350 MHz bandwidth and degrade 100 Mbps (100BASE-TX) potential performance, then SHIELDED Cable is recommended and you would then look for the STP moniker that indicates Shilded Twisted Pair.. If the cable is run near or in Air handling spaces, then you should check the local building codes pertaining to Plenum cable use as each jurisdiction can be different in definition and guidance. Riser rating is something recommended as a minimum for all interior (in wall) use. CM is for exposed runs and CMX is exteriror rating, though not necessarily UV ray resistant to degradation. CMXT and CMXT are discriptor examples that intonate exterior (X) and flooded (F) or Taped (T) for Underground Use (Direct Burial).